INNOVATION 800

The Innovation is a highly efficient tankless water heater that delivers instantaneous hot water with no storage tank or standing water that has to be heated up and then mixed down. With a reliable, scale-resistant heat exchanger and a compact footprint, the Innovation provides energy savings and lower operating costs.

FEATURES AND BENEFITS

  • Up to 99% efficiency
  • +/-4° temperature control, thanks feed-forward sensing and unmatched turndown
  • High reliability
  • Small footprint due to its tankless design
  • Reduced standby and cycling losses
  • Low NOx

Efficiencies up to 99%
The AERCO Innovation Water Heater utilizes state-of-the-art technology to easily meet highly perse, demanding commercial and industrial hot water requirements in a compact and reliable condensing design. The durable, high efficient, helical firetube heat exchanger is time tested to be impervious to thermal stress for an extended life. The all stainless steel construction maximizes longevity in the condensing application and the corrugated tubes increase effective heat transfer surface area for optimal thermal efficiencies up to 99%. Enhanced waterside flow distribution maintains constant minimum velocities across the heat exchanger; this keeps solids in suspension and greatly reduces scale dropout to maintain high-efficiency performance and long life.

Precise Temperature Control and up to 20:1 Turndown Delivers Money-Saving Precision
The advanced control system incorporates dynamic feed-forward sensing for precise modulation of its high turndown air/fuel delivery system. These controls fire the unit to accurately match load requirements and produce a tight hot water outlet temperature control. With up to 20:1 turndown, the AERCO Innovationtakes maximum advantage of its thermal efficiency, eliminating wasted fuel and reducing operating costs.

Commercial Tankless Design
The unique tankless design gives the ability to operate the system with set points of 120°F or below – saving energy and reducing the risk of scalding. Minimal water volume and maintaining continuous circulation through the unit virtually eliminate the risk of Legionella bacteria growth.

Venting Versatility
Sidewall, through–the–roof, and sealed combustion capabilities provide broad installation flexibility and savings.

Space-Saving Design
The AERCO Innovation is delivered as a single, fully assembled unit. Its small foot print, doorway size, and quiet operation make it ideal for both new construction and retrofit applications.

OPTIONS AND ACCESSORIES

AM Contractor Kit

The AM Series Boiler/Water Heater Contractor’s Kit was created with utility and convenience in mind. The Contractor’s Kit contains the most commonly requested parts, packaged in a rugged, padded carrying case for easy storage and use on the job. One Contractor’s Kit will service every size of AM; there is no need to carry multiple sets of parts for the same product line. This space-saving kit can be kept on a service truck and be used on every AM job site. The kit includes a bill of materials with illustrations for easy identification and kit replenishment.

AM Installation Kit

To help you install your new AM Series boiler or water heater, AERCO has compiled everything you need into one, convenient place, our AM Installation Kits. These kits eliminate the need to separately purchase all near-equipment piping components as well as remove any guesswork regarding which size piping is appropriate for your project. You’ll have all the components you need at your fingertips to get your AM unit installed quickly and properly so it operates at peak performance.

AM Series Cascade Manager

The AM Series Cascade Manager is a simple tool that will maximize the performance of a blank of AM Boilers or Water Heaters. The Cascade Manager is designed specifically to work with the AM Series control system.

Constant Speed Pumps

These kits include a circuit setter which allows for setting flow rates that meet the minimum allowable boiler flow rate and do not exceed the maximum. Pump Kits 99127-1/-3/-5 are in-line and permanently lubricated for ease of maintenance with a cast iron body and electrical requirement of 115V/1ph/60Hz. Pump Kits 99208-1 and 99208-2 incorporate back-pull-out design which allows service without disturbing the piping; cast iron body and electrical requirement of 115V/208-230V/1ph/60Hz.

Hydraulic Separator

These hydraulic separators establish primary-secondary piping for AM Series boiler applications. Primary-secondary piping de-couples the boiler loop from the system loop — making it independent from system loop pressure fluctuations associated with opening/closing of zone valves or 3-way valves.

Sentinel Products

Compatible with all materials found in a hydronic loop, these chemicals offer overall protection of a heating system from sludge, scale, corrosion, and freeze conditions.

This is a sample text. You can click on it to edit it inline or open the element options to access additional options for this element.